| Hardness parameter | HL, HRC, HRB, HV, HB, HS |
| Measuring range / metallic materials | See table above |
| Tensile strength U.T.S. range (steel only) | sß from 374 to 2652 mPa |
| Accuracy | Within ±6HLD |
| Memory | 48-350 groups of data |
| Impact device | D (standard) |
| Optional impact devices | DC/D+15/DL/G/C/E (see next page) |
| Workpiece max. hardness value | 996HV |
| Workpiece radius (convex/concave) | Rmin = 50mm (with support ring Rmin=10mm) |
| Min. Workpiece weight | 2~5kg on stable support |
| Workpiece min. thickness coupled | 5mm (except with impact device G: 10mm, C: 1mm) |
| Workpiece min. case hardened depth | 0.8mm |
| Indentation depth | See next page: Impact devices data |
| Power | Rechargeable batteries NiCd 1.25V (5 pcs) |
| Charger | 12V, 600mA (1.8VA) |
| Charging time | 8 hours |
| Operating temperature | 0°C to 40°C |
| Overall dimensions | 268mm x 86mm x 50mm |
| Weight | 530gr (including impact device and printer) |