The 45MG is an advanced ultrasonic thickness gage packed with standard measurement features and software options. This unique instrument is compatible with the complete range of Olympus dual element and single element thickness gage transducers.

Overview

45MG Ultrasonic Thickness Gage:
Simple Operation, Rugged, and Reliable

The 45MG is an advanced ultrasonic thickness gage packed with standard measurement features and software options. This unique instrument is compatible with the complete range of Olympus dual element and single element thickness gage transducers, making this innovative instrument an all-in-one solution for virtually every thickness gage application.

Standard Features

In its basic configuration the 45MG is a simple and straightforward gage that requires minimal operator training to tackle most common thickness gaging applications. With additional optional software options and transducers however, the 45MG can become significantly more advanced and take on applications well beyond that of a typical entry-level gage. Furthermore, most options are available individually at the time of purchase or can be added in the future as your needs change.

  • Compatible with full line of Olympus dual element transducers for thickness measurements on internally corroded metals
  • Min./Max. mode
  • Two Alarm modes
  • Differential mode
  • Time-based B-scan
  • Reduction Rate
  • Gain Adjust (standard, high, and low)
  • Password instrument lock
45MG Ultrasonic Thickness Gage

45MG with optional protective rubber boot and stand

Optional Features

From a simple corrosion gage to a multi-purpose precision thickness gage with only a few key strokes. The 45MG offers five code-activated software options that makes it one of the most versatile thickness gages in the industry.

  • Echo-to-Echo / THRU-COAT®: Using Echo-to-Echo, the true metal thickness is displayed and the thickness of the coating layer will be ignored. THRU-COAT measures metal and nonmetallic coating thicknesses, each adjusted for their correct sound velocities. There is no need to remove paint or coatings from surfaces.
  • Single Element: For very precise thickness measurements on many materials, including metals, plastics, composites, glass, and ceramics. Compatible with single element Microscan transducers ranging from 2.25 MHz to 30 MHz.
  • Single Element High Penetration: For thickness measurement on thick or highly attenuating materials such as fiberglass or cast metals. Compatible with single element Microscan transducers ranging from 0.5 MHz to 30 MHz. Included is the Single Element option.
  • Data Logger: The 45MG has a full-featured internal bidirectional alphanumeric data logger that is designed to easily store and transfer thickness readings and waveform data. Includes GageView™ interface program, a Windows-based application.
  • Live A-scan with Waveform Adjust: This optional Live A-scan mode allows users to view the ultrasound waveform (or A-scan) directly on the gage's display, verify the thickness measurement, and make manual adjustments to gain and blanking settings to maximize measurement performance in challenging applications. This helpful option features Manual Gain Adjust, Extended Blanking, First Echo Blank, Range, and Delay.

Built for Tough Environments

  • Rugged, designed for IP67
  • Explosive Atmosphere: Safe operation as defined by Class I, Division 2, Group D, as found in the National Fire Protection Association Code (NFPA 70), Article 500, and tested using MIL-STD-810G, Method 511.4, Procedure I.
  • Shock tested using MIL-STD-810G, Method 516.5, Procedure I, 6 cycles each axis, 15 g, 11 msec Half sine.
  • Vibration tested using MIL-STD-810G, Method 514.5, Procedure I, Annex C, Fig. 6, general exposure: 1 hour each axis.
  • Wide operating temperature range
  • Optional protective rubber boot with gage stand
indoor a-scan display

Indoor display setting, optional A-scan mode

Designed for Easy Operation

  • Simple keypad for right hand/left hand operation
  • Easy operator interface with direct access to most functions
  • Internal and removable MicroSD memory card storage
  • USB communication port
  • Optional alphanumeric data logger with 475,000 thickness readings or 20,000 waveforms
  • Default/Custom single element transducer setups (optional)
  • Password protected instrument lock
  • Color transflective QVGA display with indoor and outdoor color settings for superior clarity

Outdoor a-scan
Outdoor display setting, optional A-scan mode

Specifications

Measurements
Dual element transducer measurement modeTime interval from a precision delay after the excitation pulse to the first echo
Echo-to-Echo (optional)Time interval between two successive back-wall echoes to eliminate paint or coating thickness
THRU-COAT® measurement (optional)Measurement of true metal and coating thicknesses with a single back-wall echo (with D7906-SM, D7906-RM, and D7908 transducers)
Single element transducer measurement modes (optional)Mode 1: Time interval between the excitation pulse and the first back-wall echo
Mode 2: Time interval between the delay line echo and the first back-wall echo (with delay or immersion transducers)
Mode 3: Time interval between successive back-wall echoes following the first interface echo after the excitation pulse (with delay line or immersion transducers)
Thickness range0.080 mm to 635 mm (0.003 in. to 25.0 in.) depending on material, transducer, surface conditions temperature, and selected configuration (Full range requires single element option)
Material velocity range0.508 mm/μs to18.699 mm/μs (0.020 in./μs to 0.7362 in./μs)
Resolution (selectable)Low: 0.1 mm (0.01 in.)
Standard: 0.01 mm (0.001 in.)
Single Element option: 0.001 mm (0.0001 in.)
Transducer frequency rangeStandard: 2.25 MHz to 30 MHz (-3 dB) High Penetration (Single Element option): 0.50 MHz to 30 MHz (-3 dB)
General
Operating temperature range-10 °C to 50 °C (14 °F to 122 °F)
KeypadSealed, color-coded keypad with tactile and audible feedback
CaseImpact-resistant and water-resistant, gasketed case with sealed connectors. Designed for IP67.
Dimensions (W x H x D)Overall: 91.1 mm x 162 mm x 41.1 mm (3.59 in. x 6.38 in. x 1.62 in)
Weight430.9 g (0.95 lb)
Power Supply3 AA batteries/USB power supply
Battery life operating time3 AA alkaline: 20 to 21 hours
3 AA NiMH: 22 to 23 hours
AA Lithium: 35 to 36 hours
StandardsDesigned for EN15317

 

Display
Color transflective QVGA displayLiquid crystal display, display area 54.61 mm x 41.15 mm (2.15 in. x 1.62 in.)
RectificationFull wave, RF, half-wave positive, or half-wave negative (Waveform option)

 

Inputs/Outputs
USB2.0 client
Memory cardMaximum capacity: 2 GB removable MicroSD memory card

 

Internal Data Logger (Optional)
Data loggerThe 45MG identifies, stores, recalls, clears, and transmits thickness readings, waveform images, and gage configuration information through USB or MicroSD.
Capacity475,000 thickness measurements or 20,000 waveforms with thickness measurements
File names, IDs, and comments32-character file names and 20-character alphanumeric location codes with four comments per location
File structureSix standard or custom application-specific file structures
ReportsOn-gage reporting of summary with statistics, Min./Max.

Standard Package

  • 45MG digital ultrasonic thickness gage
  • AA alkaline batteries
  • 2-step test block and couplant
  • USB cable
  • User's manual on CD
  • Measurement features: Min./Max. mode, two alarm modes, Differential, mode, B-scan, Reduction Rate, Programmable Lock

Software Options

  • 45MG-SE (U8147022): Single Element option to use single element transducers with frequency range of 2.25 MHz to 30 MHz.
  • 45MG-HP (U8147023): Single Element High Penetration option to use single element transducers with frequency range of 0.5 MHz to 30 MHz.
  • 45MG-EETC (U8147021): Echo-to-Echo and THRU-COAT®
  • 45MG-WF (U8147019): Waveform option
  • 45MG-DL(U8147020): Internal data logger including GageView interface program

Optional Accessories

  • MICROSSD-ADP-2GB (U8779307): 2 GB External MicroSD memory card
  • 45MG-RPC (U8779676): Rubber protective boot with stand

 

Software Options

The 45MG offers five code-activated software options that makes it one of the most versatile thickness gages in the industry.

Echo-to-Echo / THRU-COAT® Option

Echo-to-Echo

The gage displays the true metal thickness and ignores the thickness of the coating layer, using multiple back-wall echoes:

  • Auto Echo-to-Echo
  • Manual Echo-to-Echo (with A-scan option only) that allows:
    • Gain Adjust
    • Extended Blanking
    • Echo Blanking

THRU-COAT Technology

Uses a single back-wall echo to measure true metal thickness. You can display the metal and coating thicknesses, each adjusted for their correct material sound velocities. There is no need to remove paint and coatings from surfaces. THRU‑COAT measurements use the D7906-SM, D7906‑RM, and D7908 dual element transducers.
D7906
Auto Echo to Echo Mode

Auto Echo-to-Echo mode with A-scan

Thru Coat Mode

THRU-COAT mode showing thickness of coating and steel (waveform not activated)

Manual Echo-to-Echo

Manual Echo-to-Echo adjusting the First Echo blank

Thru Coat Mode Wave

THRU-COAT mode with optional waveform

Single Element Software Option

The Single Element software option enables you to make very precise thickness measurements at a resolution of up to 0.0001 in. or 0.001 mm. Compatible with single element Microscan transducers ranging from 2.25 MHz to 30 MHz.

  • Most materials, from thin to thick
  • Plastic bottles, tubes, pipes, sheets as thin as 0.08 mm (0.003 in.)
  • Metal containers, steel coils, machined parts as thin as 0.10 mm (0.004 in.)
  • Cylinder bores, turbine blades
  • Glass bulbs, bottles
  • Thin fiberglass, rubber, ceramics, and composite materials
  • Curved areas or containers with small radii

Single Element High Penetration Software Option

This option allows you to use low frequency single element transducers (as low as 0.5 MHz) to measure thick or highly attenuating materials such as rubber, fiberglass, castings, and composites. Included is the Single Element option.

  • Most thick or sound-attenuating materials
  • Thick cast metal parts
  • Thick rubber tires, belts
  • Fiberglass boat hulls, storage tanks
  • Composite panels
  • Resolution of 0.01 mm (0.001 in.) for transducer frequencies of 0.5 MHz and 1.0 MHz

Optional Data Logger and PC Interface

The 45MG has a full-featured internal bidirectional alphanumeric data logger that is designed to easily store and transfer thickness readings and waveform data. The data logger option includes the GageView™ Interface program.

OnBoard DB Grid Vie

Onboard DB Grid View with three programmable colors

Data Logger Option

  • Internal memory of 475,000 thickness readings or 20,000 waveforms with thickness readings
  • 32 Character File name
  • 20 Character ID# (TML#)
  • 6 file formats: Incremental, Sequential, Sequential with custom point, 2-D Grid, Boiler, and Manual (from PC) GageView
  • Internal and removeable MicroSD memory cards
  • File copy with the ability to copy files between internal/removable MicroSD memory cards
  • Standard USB communication
  • Two-way transfer of single element transducer setups
  • Onboard statistical report
  • Onboard DB Grid View with three programmable colors
  • GageView™ interface program communicates with the 45MG
    • using the USB port
    • or read and write to a MicroSD memory card
  • Direct export of internal files to MicroSD memory card in Excel compatible CSV (comma-separated values) and .txt format.
color coded grid easily flags out-of-tolerance thickness condition

When viewed on your PC a color coded grid easily flags out-of-tolerance thickness conditions.

Measurement report

Measurement reports can easily be generated and printed containing measurements, ID, and other parameters.

GageView Interface Program

  • Included with the Data Logger option
  • This Windows-based application collects, creates, prints, and manages data from the 45MG.
  • Creates datasets and surveys
  • Stored data editing
  • View dataset and survey files; including thickness readings, gage setup values, and transducer setup values
  • Download and upload thickness surveys to and from the gages
  • Export surveys to spreadsheets and other programs
  • Collecting snapshot screens
  • Printing reports such as Thickness, Setup Table, Statistics, and Color Grid
  • Upgrade the 45MG software
  • Download and upload single element transducer setup files
B-scan Screen

When viewed on your PC a color coded grid easily flags out-of-tolerance thickness conditions.

Live A-Scan With Waveform Adjust

This optional Live A-scan mode allows users to view the ultrasound waveform (or A-scan) directly on the gage's display, verify the thickness measurement, and make manual adjustments to gain and blanking settings to maximize measurement performance in challenging applications. This helpful option features Manual Gain Adjust, Extended Blanking, First Echo Blank, Range, and Delay.

Transducers

Dual Element Transducers for Corrosion Gaging

All standard dual element transducers feature Automatic Probe Recognition, which automatically recalls a default V-path correction for each specific transducer.

Item NumberPart CodeFrequency
(MHz)
Connector TypeConnector LocationRange in Steel (mm)Range in Steel (in)Temperature Range °FTemperature Range °CTip Diameter (mm)Tip Diameter (in)
U8450017
Dual Transducer, 2 MHz, 0.900 in. Tip Diameter, Straight Microdot Connector, to be used with the LCMD-316-5D cable (cable is not included)
D797-SM
2MicrodotStraight3.5 - 6350.150 - 25-5 - 752-20 - 40022.90.900
U8450016
Dual Transducer, 2 MHz, 0.900 in. Tip Diameter, Right Angle Potted Integral Cable (cable is permanently attached and not replaceable)
D797
2PottedRight Angle3.5 - 6350.150 - 25-5 - 752-20 - 40022.90.900
U8454038
Dual Transducer, 5 MHz, 0.50 in. Tip Diameter, Right Angle Potted Integral Cable (cable is permanently attached and not replaceable)
D7910
5PottedRight Angle1.00 - 500.000.040 - 20.00032 -1220 - 5012.70.5
U8450021
Dual Transducer, 5 MHz, 0.434 in. Tip Diameter, Right Angle Potted Integral Cable (cable is permanently attached and not replaceable)
D799
5PottedRight Angle1.0 - 5080.040 - 20-5 - 300-20 - 150110.434
U8450007
Dual Transducer, 5 MHz, 0.434 in. Tip Diameter, Right Angle LEMO Connector, to be used with the LCLD-316-5G (cable is not included)
D790-RL
5LEMORight Angle1.0 - 5080.040 - 20-5 - 932-20 - 500110.434
U8450008
Dual Transducer, 5 MHz, 0.434 in. Tip Diameter, Straight LEMO Connector, to be used with the LCLD-316-5H cable (cable is not included)
D790-SL
5LEMOStraight1.0 - 5080.040 - 20-5 - 932-20 - 500110.434
U8450009
Dual Transducer, 5 MHz, 0.434 in. Tip Diameter, Straight Microdot Connector, to be used with the LCMD-316-5B cable (cable is not included)
D790-SM
5MicrodotStraight1.0 - 5080.040 - 20-5 - 932-20 - 500110.434
U8450011
Dual Transducer, 5 MHz, 0.434 in. Tip Diameter, Right Angle Microdot Connector, to be used with LCMD-316-5C cable (cable is not included)
D791-RM
5MicrodotRight Angle1.0 - 5080.040 - 20-5 - 752-20 - 400110.434
U8450002
Dual Transducer, 5 MHz, 0.434 in. Tip Diameter, Straight transducer with a potted integral cable (cable is permanently attached and not replaceable)
D790
5PottedStraight1.0 - 5080.040 - 20-5 - 932-20 - 500110.434
U8620225
Dual Transducer, 5 MHz, 0.20 in. Tip Diameter, 0.15 in. Element Diameter, Mini Tip Dual, Lepra/Con Connectors.
MTD705
5Lepra/ConRight Angle1.0 - 190.040 - 0.7532 - 1220 - 505.10.200
U8450010
Dual Transducer, 5 MHz, 0.434 in. Tip Diameter, Right Angle Potted Integral Cable (cable is permanently attached and not replaceable
D791
5PottedRight Angle1.0 - 5080.040 - 20-5 - 932-20 - 500110.434
U8450014
Dual Transducer, 5 MHz, 0.283 in. Tip Diameter, Straight Potted Integral Cable (cable is permanently attached and not replaceable)
D794
5PottedStraight0.75 - 500.030 - 232 - 1220 - 507.20.283
U8450018
Dual Transducer, 7.5 MHz, 0.283 in. Tip Diameter, Right Angle Potted Integral Cable (cable is permanently attached and not replaceable)
D798
7.5PottedRight Angle0.71 - 1000.028 - 4-5 - 300-20 - 1507.20.283
U8450019
Dual Transducer, 7.5 MHz, 0.350in. Tip Diameter, Right Angle Potted Integral Cable (cable is permanently attached and not replaceable).
D798-LF
7.5PottedRight Angle0.71 - 1000.028 - 4-5 - 300-20 - 1508.90.35
U8450020
Dual Transducer, 7.5 MHz, 0.283 in. Tip Diameter, Straight Microdot Connector, to be used with the LCMD-316-5J cable (cable is not included).
D798-SM
7.5MicrodotStraight0.71 - 1000.028 - 4-5 - 300-20 - 1507.20.283
U8454013
Dual Transducer, 7.5 MHz, 0.350 in. Tip Diameter, Right Angle Potted Connector
D7226
7.5PottedRight Angle0.71 - 1000.028 - 4-5 - 300-20 - 1508.90.35
U8450012
Dual Transducer, 10 MHz, 0.283 in. Tip Diameter, Straight Potted Integral Cable (cable is permanently attached and not replaceable)
D792
10PottedStraight0.5 - 250.020 - 132 - 1220 - 507.20.283
U8450013
Dual Transducer, 10 MHz, 0.283 in. Tip Diameter, Right Angle Potted Integral Cable (cable is permanently attached and not replaceable).
D793
10PottedRight Angle0.5 - 250.020 - 132 - 1220 - 507.20.283

Single Element Transducers for Precision Thickness Measurements

Contact Transducers

FrequencyElement Diameter
Transducers

Item Number
mminches
0.5251.00M101-SB*U8400017
1.0251.00M102-SB*U8400018
1.0130.5M103-SB*U8400020
2.25130.5M106-RMU8400023
M106-SMU8400025
2.25130.5M1036U8400020

5.0

130.5M109-RMU8400027
M109-SMU8400028
5.060.25M110-RMU8400030
M110-SM
M110H-RM**
U8400031
U8400029
1060.25M112-RM
M112-SM
U8400034
U8400035
U8400033
M112H-RM**U8400033
1030.125M1016U8400015
2030.125M116-RMU8400038
M116-SMU8400039
2030.125M116H-RM**U8400037

*These transducers can only be used with the High Penetration software option.
**Use with spring loaded holder.

Sonopen® Transducers

The Sonopen transducer has a replaceable delay line that is tapered to a small contact area. This transducer makes reliable thickness measurements in applications such as turbine blades and tight radii on plastic containers.

Sonopen - 15 MHz, 3 mm (0.125 in.) transducer

 

Straight HandleRight Angle Handle45° Handle
PartItem
Number
PartItem
Number
PartItem
Number
V260-SMU8411019V260-RMU8411018V260-45U8411017

Sonopen - Replaceable Delay Lines

Tip DiameterPartItem
Number
mminches
2.00.080DLP-3U8770086
1.50.060DLP-302U8770088
2.00.080DLP-301†U8770087

High temperature delay for use up to 175°C (350°F)

Immersion Transducers

Panametrics Microscan immersion transducers are designed to transmit and receive ultrasound in water. Thickness measurements by immersion technique are often preferred when the test piece has a complex geometry or in on-line applications. Typical off-line applications include wall thickness measurements on small diameter plastic or metal tubing, scanned or rotary measurements and thickness measurements on sharply curved parts. Transducer focusing may be necessary depending on the application.

 

Frequency
(MHz)
Element Diameter
Transducer


Item Number

mmin.
2.25130.50M306-SUU8410027
5.0130.50M309-SUU8420001
5.060.25M310-SUU8420004
1060.25M312-SUU8420008
1560.25M313-SUU8420009
2030.125M316-SUU8420011

 

RBS-1 Immersion Tank

The RBS-1 immersion tank is designed to simplify ultrasonic thickness measurements using immersion techniques.

Delay Line Transducers

Microscan delay line transducers provide excellent performance on very thin materials, at elevated temperatures,or with applications that require a high degree of thickness resolution.

 

Freq.
(MHz)
Element
Diameter

Transducer


Item
Number


Holders

Item
Number
mminches
0.5251.00M2008*U8415001--
2.25130.50M207-RBU8410017--
5.0130.50M206-RBU8410016--
5.060.25M201-RMU8410001--
5.060.25M201H-RMU84110302127U8770408

10

6

0.25
M202-RMU8410003
-

-
M202-SMU8410004
1060.25M202H-RMU85070232127U8770408

10


3


0.125
M203-RMU8410006
-

-
M203-SMU8410007

20

3

0.125
M208-RMU8410019
-

-
M208-SMU8410020
2030.125M208H-RMU84100182133U8770412
2030.125M2055**U8415013--
3060.25V213-BC-RM**U8411022--

*These transducers can only be used with the High Penetration software option.
**Delay line is not replaceable on these transducers.

Replaceable Delay Lines

Delay lines function as a protective buffer between the surface of the test piece and the transducer element.

 

Element
Diameter

Delay LineMaximum Thickness
Measurement Limit*
mminchesPartItem
Number
Steel - Mode 2Steel - Mode 3Plastic - Mode 2
mminchesmminchesmminches
130.50DLH-2U8770062251.0130.5130.5
60.25DLH-1U8770054251.0130.5130.50
30.125DLH-3U8770069130.550.250.2

 

Additional Products

Couplants

Liquid couplant is almost always necessary to provide acoustic coupling between the transducer and the test piece. We offer various types of couplants to suit virtually all applications.

Calibration Test Blocks

Test blocks are necessary for the calibration of ultrasonic thickness gages and should be used to maintain and verify the accuracy, dependability, and reliability of ultrasonic measurements. Blocks are held to tighter tolerances than stated in ASTM E797 code. Metric test blocks are available.

Transducer Cables

A wide selection of transducer cables suitable for all ultrasonic thickness gaging instrumentation.

  • Standard
  • Waterproof
  • Heavy Duty
    • Teflon
    • Armored PVS Jacket
    • Armored Silicone Jacket
    • Stainless Steel

Multimedia